Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

ManufacturerKalstein

Description

Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 is a state-of-the-art analytical tool crafted by Kalstein for the precise measurement of color and appearance in various laboratory and industrial applications. This spectrophotometer is distinctive due to its pulsed xenon lamp, delivering long-lasting service life and exceptional stability for each test. Its 7-inch TFT touchscreen and advanced optical geometry (reflective d/8 and transmissive d/0, with UV inclusion or exclusion) provide reliable assessments on both solid samples and transparent or translucent liquids. The dual-array 256-element CMOS sensor along with an automatic aperture identification system ensures remarkable accuracy for every type of sample, making it an ideal choice for researchers seeking consistent, detailed results.

Market Price

The YR05475 spectrophotometer offers an excellent balance of features and affordability, positioned in the market between $3,445 and $4,000 USD. This competitive pricing makes it accessible for businesses in sectors such as plastics, paint, food, cosmetics, and medicine where accurate color analysis is critical. For an industry-specific quotation or to explore tailored options, access the Kalstein Plus platform. Here, you can effortlessly request a personalized and obligation-free quote, adapting to your precise needs.

Frequently Asked Questions

  • Can the YR05475 measure both transparent and opaque samples?
    Absolutely, this spectrophotometer is designed to effectively analyze both opaque and translucent materials, including clear liquids and solid materials.
  • How much data can the YR05475 store?
    The model can store up to 20,000 results, which is beneficial for comprehensive and detailed test data monitoring.
  • Are the measurement apertures adjustable?
    Yes, the YR05475 provides three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), ensuring flexibility for various sample types.

Advantages and Disadvantages

The YR05475 stands out with its temperature compensation system, ensuring accuracy even in fluctuating environmental conditions. It offers comprehensive lighting options (LED and UV) and features an ergonomic design for comfortable use in demanding settings. A potential downside is the need for periodic calibration in high-usage situations to maintain optimal accuracy.

Field Use

This spectrophotometer is excellently suited for quality control and product development laboratories across industries with high demands, such as automotive, cosmetics, medical, and food sectors. Its capability to measure both reflectance and transmittance across diverse materials optimizes the quality verification process, ensuring high standards at every production stage.

Recommendations

To maximize the functionality and longevity of the YR05475, it is recommended to perform periodic calibrations and maintain the device in a clean, stable environment. Adjusting the measurement aperture according to sample type and specific test conditions will enhance accuracy and result consistency. Visit Kalstein Plus today to request your customized quote and explore how the YR05475 Benchtop Spectrophotometer can transform your quality control and color analysis processes with precision and reliability.

Features

  • Pulsed xenon lamp for longevity and stability
  • 7-inch TFT touchscreen for intuitive operation
  • Dual-array 256-element CMOS sensor
  • Automatic aperture identification with adjustable settings
  • Storage capacity of 20,000 records

Technical Specifications

Model YR05475 (Pulsed xenon lamp)
Optical Geometry Reflectance: d/8 (SCI⪰ Include UV/Exclude UV)
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003)
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size Φ 154mm
Light Source Device 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360-780nm
Wavelength Pitch 10nm
Semiband Width 5nm
Reflectance Range 0~200%
Measuring Aperture Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component Reflectance: SCI&SCE
Transmittance: SCI&SCE
Color Space CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy
Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99
Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle 2° & 10°
Illuminants D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed Data Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
Measuring Time About 2.4s (Measure SCI & SCE about 5s)
Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
Size 370×300×200mm
Weight About 9.6kg
Power Supply DC 24V, 3A Power Adapter
Light Source Device Life 5 years, more than 3 million times measurements.
Display 7″ TFT Capacitive Screen-touch Display
Data Port USB & Print serial port
Data Storage Standard 2000 Pcs, Sample 20000 Pcs
Language Simplified Chinese, Traditional Chinese, English,
Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation)
Storage Environment Temperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard Accessory Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber,
Optional Accessory Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Additional information

Weight 12,5 kg
Dimensions 51 × 45 × 33 cm

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.