The Automatic Nucleic Acid Extractor YR01869-2 is a state-of-the-art instrument designed to enhance the efficiency of nucleic acid extraction processes. Featuring advanced rotary mixing technology, this device offers the capability to perform multiple simultaneous extractions without cross-interference, making it a versatile choice for laboratories with varied assay needs. Its compact, flexible design, complemented by a 6.86-inch touch screen and smart device compatibility, has garnered accolades such as the Red Dot Design Award 2021. Perfect for genetic research and clinical diagnostics, the YR01869-2 promises user-friendly operation, exceptional flexibility, and robust performance.
Market Price
The market value of the Automatic Nucleic Acid Extractor YR01869-2 ranges approximately between $8,500 and $9,100 USD. This cutting-edge piece of laboratory equipment represents a significant investment, offering unparalleled benefits in terms of functionality and technology for research facilities. To explore exclusive offers and get a personalized quote, consider using the Kalstein Plus platform, designed to provide tailored pricing and additional advantages such as specialized technical support.
Frequently Asked Questions
- What sample types can the YR01869-2 process? The device can handle a diverse array of samples, particularly those involving precise nucleic acid extractions like DNA and RNA.
- Is the YR01869-2 user-friendly? Absolutely. It features an intuitive touch screen interface and remote control from mobile devices, ensuring ease of use and efficiency.
- How do I maintain optimal performance of the YR01869-2? Regular cleaning and system updates are crucial, as is following manufacturer maintenance guidelines to maintain peak performance.
Advantages and Disadvantages
Advantages:
- Versatile Performance: Capable of managing 16 x n sample extractions simultaneously.
- Automated System: Features like automatic reagent identification and remote updates enhance efficiency.
- Enhanced Safety Features: Equipped with UV lamps and HEPA filtration for reduced contamination and precise results.
- Portable Design: Its compact form factor facilitates experiments in various settings.
Disadvantages:
- Investment Cost: The price might be prohibitive for small labs with limited budgets.
- Needs Specialized Maintenance: Requires skilled personnel for maintenance, given its advanced features.
Product Use in the Field
This extractor is extensively used in genetic laboratories, clinical diagnosis, and biotech applications, where its ability to execute rapid and simultaneous nucleic acid extractions is prized. It’s adaptable for use in hospitals, forensic labs, and varied research environments, providing critical support where agility and precision are vital for immediate results.
Recommendations
To optimize the effectiveness of the YR01869-2, adhere to manufacturer-recommended maintenance, such as consistent device cleaning and protocol updates. Leverage its multi-tasking capabilities to boost lab productivity by running parallel assays. Furthermore, employing its UV disinfection and HEPA filtration systems is crucial to avoid cross-contamination, thereby ensuring the accuracy of experimental outcomes.
Features
- Model: YR01869-2
- 16 Sample Throughput with Rotary Mixing
- Mobile Device Control and Full-Color Touch Screen
- Automatic Reagent and Protocol Management
- UV and Ozone Disinfection
- HEPA Filtration with Negative Pressure System
- Portable and Compact Design
- Temperature Control and Accuracy within 30°C to 120°C
- User-Friendly Interface with Multiple Language Support
Technical Specifications
| Model | YR01869-2 |
| Throughput | 16 |
| Processing Volume | 20-1700μL |
| Sample Processing Volume | 200-500μL |
| Compatible Consumables | Customized 96-deep-well plates, single 6-strip tubes |
| Inter-well Difference | CV≤3% |
| Mixing Method | Rotary mixing |
| Rotary Speed | 100~3000rpm |
| Temperature Control Range | Temperature control separately for lysis and elution. |
| Temperature range from 30°C to 120°C. | |
| Temperature Control Accuracy | Heating speed: 4.0±0.2°C/s. |
| Temperature accuracy: ±1.0°C. | |
| Temperature uniformity:≤1.0°C. | |
| Languages | Chinese/English |
| Protocol Management | Flexible to create, edit and delete protocols |
| Operation Mode | Mode 1: Android systems in smartphones/tablets |
| Mode 2: 6.86 inch full-color LCD screen | |
| Automatic Control | Automatic opening and closing of the experiment cabin |
| Reagent Identification | Automatic identification of reagent information and running the assays |
| Mixing Sleeve Monitoring | Real-time monitoring of the mixing sleeves status in experiment |
| Magnetic Bead Residue | ≤1% |
| Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
| Disinfection | Ozone + UV disinfection |
| Auto Power-off | Auto power-off after UV disinfection |
| Negative-Pressure Filtration | Negative pressure HEPA filtration module |
| Connection Port Type | USB port |
| Weight | 7.4Kg (net) |
| Instrument Dimensions | 210mm(L)*229mm(W)*242mm(H) |
| Power Supply | AC220V, 50Hz |