Kalstein

Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

SKU:YR05475 · By Kalstein

Category:Benchtop Spectrophotometer

Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

Pulsed Xenon lamp Benchtop Spectrophotometer YR05475 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.

Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 is a state-of-the-art analytical tool crafted by Kalstein for the precise measurement of color and appearance in various laboratory and industrial applications. This spectrophotometer is distinctive due to its pulsed xenon lamp, delivering long-lasting service life and exceptional stability for each test. Its 7-inch TFT touchscreen and advanced optical geometry (reflective d/8 and transmissive d/0, with UV inclusion or exclusion) provide reliable assessments on both solid samples and transparent or translucent liquids. The dual-array 256-element CMOS sensor along with an automatic aperture identification system ensures remarkable accuracy for every type of sample, making it an ideal choice for researchers seeking consistent, detailed results.

Market Price

The YR05475 spectrophotometer offers an excellent balance of features and affordability, positioned in the market between $3,445 and $4,000 USD. This competitive pricing makes it accessible for businesses in sectors such as plastics, paint, food, cosmetics, and medicine where accurate color analysis is critical. For an industry-specific quotation or to explore tailored options, access the Kalstein Plus platform. Here, you can effortlessly request a personalized and obligation-free quote, adapting to your precise needs.

Frequently Asked Questions

  • Can the YR05475 measure both transparent and opaque samples?
    Absolutely, this spectrophotometer is designed to effectively analyze both opaque and translucent materials, including clear liquids and solid materials.
  • How much data can the YR05475 store?
    The model can store up to 20,000 results, which is beneficial for comprehensive and detailed test data monitoring.
  • Are the measurement apertures adjustable?
    Yes, the YR05475 provides three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), ensuring flexibility for various sample types.

Advantages and Disadvantages

The YR05475 stands out with its temperature compensation system, ensuring accuracy even in fluctuating environmental conditions. It offers comprehensive lighting options (LED and UV) and features an ergonomic design for comfortable use in demanding settings. A potential downside is the need for periodic calibration in high-usage situations to maintain optimal accuracy.

Field Use

This spectrophotometer is excellently suited for quality control and product development laboratories across industries with high demands, such as automotive, cosmetics, medical, and food sectors. Its capability to measure both reflectance and transmittance across diverse materials optimizes the quality verification process, ensuring high standards at every production stage.

Recommendations

To maximize the functionality and longevity of the YR05475, it is recommended to perform periodic calibrations and maintain the device in a clean, stable environment. Adjusting the measurement aperture according to sample type and specific test conditions will enhance accuracy and result consistency. Visit Kalstein Plus today to request your customized quote and explore how the YR05475 Benchtop Spectrophotometer can transform your quality control and color analysis processes with precision and reliability.

Features

  • Pulsed xenon lamp for longevity and stability
  • 7-inch TFT touchscreen for intuitive operation
  • Dual-array 256-element CMOS sensor
  • Automatic aperture identification with adjustable settings
  • Storage capacity of 20,000 records

Technical Specifications

ModelYR05475 (Pulsed xenon lamp)
Optical GeometryReflectance: d/8 (SCI⪰ Include UV/Exclude UV)
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003)
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Integrating Sphere SizeΦ 154mm
Light Source Device360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Pitch10nm
Semiband Width5nm
Reflectance Range0~200%
Measuring ApertureReflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE
Transmittance: SCI&SCE
Color SpaceCIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy
Color Difference FormulaΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99
Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle2° & 10°
IlluminantsD65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed DataSpectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
Measuring TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
Size370×300×200mm
WeightAbout 9.6kg
Power SupplyDC 24V, 3A Power Adapter
Light Source Device Life5 years, more than 3 million times measurements.
Display7″ TFT Capacitive Screen-touch Display
Data PortUSB & Print serial port
Data StorageStandard 2000 Pcs, Sample 20000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English,
Working EnvironmentTemperature: 0~40℃; Humidity: 0~85% (No Condensation)
Storage EnvironmentTemperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard AccessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber,
Optional AccessoryMicro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Technical specifications

DimensionsL 51 × W 45 × H 33 cm
Weight12.5 kg
ManufacturerKalstein

Video Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

Frequently asked questions

How to know the prices of Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

To know the price of Pulsed Xenon lamp Benchtop Spectrophotometer YR05475, please send us an email with your request through the contact form AQUI.

What are the delivery times for Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.