Description
The Grating Spectrophotometer YR05493 from Kalstein is a state-of-the-art instrument designed for precise color analysis across diverse industries such as electronics, plastics, textiles, automotive, cosmetics, and food. Equipped with three measurement apertures (φ8 mm, φ4 mm, 1×3 mm), this device offers the adaptability needed to accommodate samples of varying sizes. Utilizing advanced 1000-line grating technology and a dual silicon photodiode array sensor, the YR05493 ensures stable and accurate color measurements within the visible spectrum of 400 to 700 nm. Its ergonomic design, coupled with a dual d/8 optical structure, supports both SCI and SCE measurements, complying with international standards like CIE No.15 and ASTM E1164, making it an indispensable tool for quality control in laboratory and production settings.
Market Price
The YR05493 is an invaluable investment for businesses striving to enhance precision and efficiency in color quality control. Market prices range approximately from $8500 to $9100 USD, depending on selected configurations and accessories. For a personalized experience, you can effortlessly obtain a quote or generate an instant quote on the Kalstein Plus platform, streamlining your purchasing journey significantly.
Frequently Asked Questions
- What applications is the YR05493 recommended for?
It is exceptionally suited for color control in industries like plastics, textiles, ceramics, printing, and is notably effective for fluorescent samples. - Is the YR05493 compatible with PCs?
Absolutely, it comes with color management software for PC, allowing detailed analysis and comprehensive management of color quality data. - What is the storage capacity?
This model boasts the capability to store up to 1,000 standards and 30,000 samples, ideal for meticulous and organized record-keeping.
Advantages and Disadvantages
The YR05493 provides significant advantages, including high precision with a standard deviation of ΔE*ab of just 0.03, multi-aperture adaptability, and compatibility with various color spaces and illuminants. Its USB and Bluetooth 4.2 connectivity enable swift data transfer. However, its limitation within the 400-700 nm visible spectrum might not cater to applications demanding a broader wavelength range.
Field Applications
The YR05493 finds utility in fields prioritizing high color accuracy, such as plastics, textiles, coatings, and ceramics manufacturing. Its capability to measure in both SCI and SCE modes, along with adaptable apertures, ensures it meets each sample’s unique needs, delivering consistent results. It is also invaluable for color verification in signage products and reflective films, establishing itself as an essential instrument in laboratories and production lines.
Recommendations
To maximize the performance of the YR05493, regular calibration is vital, and it should be housed in a clean, dust-free environment. With a lithium-ion battery facilitating up to 6,000 measurements over 8 hours, consistent recharging is advised. For tailored information on how the YR05493 Grating Spectrophotometer can enhance your industry’s color control precision and efficiency, request a personalized quote or generate a quick quote using Kalstein Plus.
Features
- Three adaptable measurement apertures for various sample sizes
- Stable and precise 1000-line grating technology
- High storage capacity for extensive sample recording
- USB and Bluetooth 4.2 connectivity for data transfer
- Ergonomic design with dual optical structure for SCI/SCE measurements
- Conforms to international standards for accurate and reliable performance
Technical Specifications
| Model | YR05493 |
| Optical Geometry | D/8 (diffused illumination, 8-degree viewing angle) |
| SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source | |
| Conforms to CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
| Characteristic | 3 measuring apertures for accurate color analysis and transmission in laboratory |
| It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. | |
| Integrating Sphere Size | Φ40mm |
| Light Source | Combined full spectrum LED light source, UV light source |
| Spectrophotometric Mode | Flat Grating |
| Sensor | Silicon photodiode array (double row 40 groups) |
| Wavelength Range | 400~700nm |
| Wavelength Interval | 10nm |
| Semiband Width | 10nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture | 3 apertures: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm;LAV:1x3mm |
| LAV1x3mm: Slightly poor accuracy, can be used for color test | |
| Specular Component | SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2)) |
| Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
| Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
| YI(ASTM D1925,ASTM 313), | |
| Metamerism Index MI, | |
| Staining Fastness, Color Fastness, Color Strength, Opacity, | |
| 8° Glossiness,555 tone classification | |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
| Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
| Chromaticity value: MAV/SCI, within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 |
| (Average for 12 BCRA Series II color tiles) | |
| Measurement Mode | Single Measurement, Average Measurement(2-99times) |
| Locating Method | Camera Locating,stabilizer cross position |
| Dimension | L*W*H=129X76X217mm |
| Weight | Approx 600g |
| Battery | Li-ion battery, 6000 measurements within 8 hours |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB, Bluetooth 4.2 |
| Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
| Language | Simplified Chinese, English, traditional Chinese |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture,1x3mm tip aperture |
| Optional Accessory | Micro Printer, Powder Test Box, Holding base |
| Notes | The specifications are subject to change without notice. |